Crown Micro-Tech MT-1000 Technické informace Strana 1

Procházejte online nebo si stáhněte Technické informace pro Audio zesilovače Crown Micro-Tech MT-1000. Crown Micro-Tech MT-1000 Technical information Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 39
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
ODEP
CH1 CH2
POWER
OFF
ODEP
CH1 CH2
POWER
OFF
Models:
Micro-Tech 600, 1200 & 2400
Micro-Tech 601, 1201 & 2401
Some models may be exported under the name
Amcron
.
®
102990-1
7/97
© 1997 by Crown International, Inc., P.O. Box 1000, Elkhart, IN 46515-1000 U.S.A. Telephone: 219-294-8000.
Fax: 219-294-8329. Micro-Tech amplifiers are produced by the Professional Audio Division of Crown
International, Inc. Trademark Notice:
Grounded bridge
is a trademark and
Amcron
,
®
Crown
,
®
Techron
,
®
Micro-Tech
,
®
ODEP
®
and
TEF
®
are registered trademarks of Crown International, Inc. Other trademarks are
the property of their respective owners.
®
®
Commercial
Audio
LL 32521C
(MT-600 & 1200)
120 VAC North
American
Units Only:
Commercial
Audio
E106377
(MT-600 & 1200)
Approved for
THX Theatre
Systems
(MT-600 & 1200)
®
For
Canada
(MT-2400)
Zobrazit stránku 0
1 2 3 4 5 6 ... 38 39

Shrnutí obsahu

Strany 1 - Units Only:

ODEPCH1 CH2POWEROFFODEPCH1 CH2POWEROFFModels:Micro-Tech 600, 1200 & 2400Micro-Tech 601, 1201 & 2401Some models may be exported under the name

Strany 2 - FULL WARRANTY

Page 10Micro-Tech 600/1200/2400 Power Amplifiers3 Installation3.1 MountingMicro-Tech amplifiers are designed for standard 19-inch (48.3 cm) rack moun

Strany 3 - IMPORTANT

Page 11Micro-Tech 600/1200/2400 Power Amplifiersthe rack so it blows outside air into the space betweenthe door and the front of the amplifiers. This

Strany 4 - CONTENTS

Page 12Micro-Tech 600/1200/2400 Power AmplifiersCAUTION: In Stereo mode, never tie the amplifier’soutputs directly together, and never parallel themw

Strany 5 - ILLUSTRATIONS

Page 13Micro-Tech 600/1200/2400 Power AmplifiersCAUTION: Only connect balanced equipment(meters, switches, etc.) to the Bridge-Mono output.Both sides

Strany 6

Page 14Micro-Tech 600/1200/2400 Power Amplifiers3.3.4 Input ConnectionThe balanced phone jack inputs have a nominal im-pedance of 20 K ohms (10 K ohm

Strany 7 - 1 Welcome

Page 15Micro-Tech 600/1200/2400 Power AmplifiersSOLVING INPUT PROBLEMSSometimes large subsonic (subaudible) frequenciesare present in the input signa

Strany 8 - 2 Facilities

Page 16Micro-Tech 600/1200/2400 Power Amplifiersconductors that could bisect the magnetic field.Ground loops will also occur when the input and out-p

Strany 9 - Fig. 2.2 Rear Facilities

Page 17Micro-Tech 600/1200/2400 Power Amplifiers1. Note the load resistance of the loudspeakers connectedto each channel of the amplifier. Mark this

Strany 10 - 3 Installation

Page 18Micro-Tech 600/1200/2400 Power AmplifiersA better approach is to fuse each driver independently.This allows you to apply the most appropriate

Strany 11 - STEREO MODE

Page 19Micro-Tech 600/1200/2400 Power Amplifiers4 Operation4.1 PrecautionsAlthough your amplifier is protected from internal andexternal faults, you

Strany 12 - BRIDGE-MONO MODE

WORLDWIDESUMMARY OF WARRANTYThe Crown Audio Division of Crown International, Inc., 1718 WestMishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrant

Strany 13 - PARALLEL-MONO MODE

Page 20Micro-Tech 600/1200/2400 Power Amplifiers4.3.4 Transformer Thermal ProtectionAll Micro-Tech amplifiers have transformer thermal pro-tection. T

Strany 14 - Twin-lead shielded cable

Page 21Micro-Tech 600/1200/2400 Power Amplifiers4.4 ControlsThe power switch is located on the front panel so youcan easily turn the amplifier on or

Strany 15 - Input Wiring Tips

Page 22Micro-Tech 600/1200/2400 Power Amplifiers5 Technical Information5.1 OverviewMicro-Tech amplifiers incorporate several technologi-cal advanceme

Strany 16 - Use Good Connectors

Page 23Micro-Tech 600/1200/2400 Power AmplifiersFAULTONLY ONE CHANNEL SHOWNNPN HIOUTPUTSTAGENPN LOWOUTPUTSTAGEPNP LOWOUTPUTSTAGEPNP HIOUTPUTSTAGERED(

Strany 17

Page 24Micro-Tech 600/1200/2400 Power AmplifiersFrom the error amp, the voltage translator stage routesthe signal to the Last Voltage Amplifiers (LVA

Strany 18 - Micro-Tech

Page 25Micro-Tech 600/1200/2400 Power Amplifiers6 SpecificationsThe following applies to units in Stereo mode with with both channelsdriven into 8 oh

Strany 19 - 4 Operation

Page 26Micro-Tech 600/1200/2400 Power AmplifiersControlsPower: A front panel rocker switch used to turn the ampli-fier on and off.Level: A back panel

Strany 20

Page 27Micro-Tech 600/1200/2400 Power AmplifiersCrown specifications are guaranteed for three years.In an effort to provide you with as much informat

Strany 21 - 4.5 Filter Cleaning

Page 28Micro-Tech 600/1200/2400 Power AmplifiersFig. 6.3 Micro-Tech 2400 Minimum Power Matrix82Micro-Tech 2400 – Minimum Guaranteed Power (Watts)Ste

Strany 22 - 5 Technical Information

Page 29Micro-Tech 600/1200/2400 Power AmplifiersMaximum Power SpecificationsCrown’s maximum power specifications represent the largest amount of outp

Strany 23 - ONLY ONE CHANNEL SHOWN

Printed onrecycled paper.WATCH FOR THESE SYMBOLS:The lightning bolttriangle is used toalert the user to therisk of electric shock.The exclamation poin

Strany 24

Page 30Micro-Tech 600/1200/2400 Power Amplifiers82Stereo(both channelsdriven)Bridge-Mono(balanced output)Parallel-Mono116446855003201,3951,0406651,34

Strany 25 - 6 Specifications

Page 31Micro-Tech 600/1200/2400 Power AmplifiersFig. 6.7 Typical Frequency ResponseFig. 6.8 Typical Damping FactorFig. 6.9 Typical Output Impedanc

Strany 26

Page 32Micro-Tech 600/1200/2400 Power AmplifiersTECHRONTEF®+45˚0˚–45˚100 1 K 10 K 20 KFREQUENCY (Hz)100 1 K 10 K 20 KFREQUENCY (Hz)dBTECHRONTEF®–81–7

Strany 27 - Minimum Power Specifications

Page 33Micro-Tech 600/1200/2400 Power Amplifiers–102100 1 K 10 K 20 KFREQUENCY (Hz)dBTECHRONTEF®–96–90–84–78–72–66100 1 K 10 K 20 KFREQUENCY (Hz)dBTE

Strany 28 - Micro-Tech 1200 –

Page 34Micro-Tech 600/1200/2400 Power AmplifiersHere are the equations used to calculate the data pre-sented in Figures 7.1, 7.2 and 7.3:AC Mains Pow

Strany 29 - Maximum Power Specifications

Page 35Micro-Tech 600/1200/2400 Power AmplifiersFig. 7.2 Micro-Tech 1200 Power Draw, Current Draw andThermal Dissipation at Various Duty Cycles8 Ohm

Strany 30 - Micro-Tech 2400 –

Page 36Micro-Tech 600/1200/2400 Power Amplifiers8 Accessories8.1 Cooling Fan OptionsEvery Micro-Tech amplifier has a built-in high-velocityfan that p

Strany 31 - 20 100 1 K 10 K 20 K

Page 37Micro-Tech 600/1200/2400 Power Amplifiers9 ServiceThis unit has very sophisticated circuitry which shouldonly be serviced by a fully trained t

Strany 33

Detach and send with unit.Crown Factory Service InformationShipping Address: Crown International, Inc., Factory Service, Plant 2 SW, 1718 W. Mishawaka

Strany 34 - Thermal Dissipation

Page 4Micro-Tech 600/1200/2400 Power AmplifiersCONTENTS1 Welcome ... 71.1 Unpa

Strany 35 - Micro-Tech 2400

Page 5Micro-Tech 600/1200/2400 Power AmplifiersILLUSTRATIONS1.1Micro-Tech Amplifier ...

Strany 36 - 8 Accessories

Page 6Micro-Tech 600/1200/2400 Power Amplifiers

Strany 37 - 9 Service

Page 7Micro-Tech 600/1200/2400 Power Amplifiers1 WelcomeCongratulations on your purchase of a Micro-Tech®professional power amplifier. Crown’s Micro-

Strany 38

Page 8Micro-Tech 600/1200/2400 Power AmplifiersFig. 2.1 Front FacilitiesODEPCH1 CH2POWEROFFAB CC D2 FacilitiesA. Filter GrilleThis metal grille supp

Strany 39 - NATURE OF PROBLEM

Page 9Micro-Tech 600/1200/2400 Power AmplifiersFig. 2.2 Rear FacilitiesCAUTION:THIS COVER IS NECESSARY FOREFFICIENT COOLING OF THE AMPLIFIER.REMOVE

Komentáře k této Příručce