Crown FMX250 Uživatelský manuál Strana 14

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 44
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 13
2–6
Installation
4) Locate the cable assembly with the "N" type connectors that are connected 
together with a "N" style Female "T". Each of the ends of this assembly 
should connect to the "RF Input" located on the back panel of each PA. This 
cable is RG-11 type and is labeled as such. See Illustration 2-8 for location of 
RF Input. The center of this assembly should have an open female "N" 
connector. Locate the 3 foot RG-214 cable (labeled 101635-1) and attach it 
between this point and the RF output of the FMX250. Refer to Illustration 4-3 
on page 4-3 of section 4 for further information.
Illustration 2-8 I/O port locations
Back of 
Power Amp
Back of 
Transmitter 
Controller
DB-25 I/O port
DB-25 I/O port
RF Input
3) Locate the DB-25 Male-to-Male cables and connect between 'I/O' port on 
both of the PA's and the ports labled PA1 and PA2 on the Transmitter 
Controller with the top PA going to PA1. The I/O ports and PA input ports 
for each is shown in Illustration 2-8.
Zobrazit stránku 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 43 44

Komentáře k této Příručce

Žádné komentáře